CALCULATOR · HYDROGEN
Hydrogen storage mass
How many kilograms of hydrogen a pressure vessel or cylinder bank holds, using real-gas density rather than the ideal gas law. Results update as you type.
The vessel’s internal (water) volume, from its data plate.
Settled pressure at the temperature below, up to 1,000 bar.
The lowest pressure you can draw down to. Sets the usable mass.
−53 to 150 °C.
Gas at a uniform temperature.
How the calculator works
At high pressure, hydrogen packs in less tightly than the ideal gas law predicts. The compressibility factor Z measures how much: Z = 1 for an ideal gas, and Z rises above 1 for hydrogen as pressure climbs.
- Density: ρ = p M / (Z R T), with M = 2.01588 g/mol and R = 8.314 J/(mol·K).
- Z: from the NIST equation of Lemmon, Huber and Leachman (2008), stated to hold from 220 to 1,000 K and up to 700 bar.
- Mass: density × water volume × number of vessels. Usable mass is the difference between full and minimum pressure.
- Energy: 33.33 kWh per kg (lower heating value). Normal volume is at 0 °C and 1.01325 bar.
Worked example
A standard 50 L industrial cylinder at 200 bar g and 15 °C, drawn down to 10 bar g:
| Step | Calculation | Result |
|---|---|---|
| Absolute pressure | 200 + 1.013 bar | 20.10 MPa |
| Compressibility | NIST equation at 288.15 K | Z = 1.127 |
| Density | 20.10 × 10⁶ × 0.002016 / (1.127 × 8.314 × 288.15) | 15.01 kg/m³ |
| Mass stored | 15.01 × 0.050 | 0.750 kg |
| Usable to 10 bar g | 0.750 − 0.046 | 0.704 kg |
| Ideal gas law | same sum with Z = 1 | 0.846 kg (13% too high) |
At 700 bar and 15 °C the same method gives 40.2 kg/m³, the figure usually quoted for vehicle tanks. The ideal gas law would say 59 kg/m³, almost half as much again.
Things that change the answer
- Fill temperature: fast filling heats the gas. A tank that reads full while hot holds less once it cools to ambient.
- Usable pressure: a compressor or dispenser that needs a high suction pressure leaves more hydrogen in the bank.
- Vessel growth: composite vessels swell slightly under pressure; data-plate volume is close enough for sizing.
- Design codes: vessel design, relief sizing and separation distances follow their own codes. This tool only counts the gas.
Need help sizing hydrogen storage or a refuelling buffer? Talk to Avoltium about a one-hour expert call.