RO Recovery Calculator

CALCULATOR · WATER TREATMENT

RO recovery, reject and permeate quality

Flow and salt balance for a reverse osmosis unit: permeate, concentrate (reject), their TDS and the concentration factor. Results update as you type.

Permeate flow / feed flow. Brackish water often 70 to 80%; seawater often 40 to 50%.

From the membrane data sheet; real systems often run a little below the nominal figure.

FEED FLOW–
PERMEATE FLOW–
CONCENTRATE (REJECT) FLOW–
PERMEATE TDS–
CONCENTRATE TDS–
CONCENTRATION FACTOR–
CONCENTRATE OSMOTIC PRESSURE–

Mass balance only.

How the calculator works

  • Flows: permeate Qp = R × Qf; concentrate Qc = Qf − Qp, where R is the recovery.
  • Permeate TDS: the membrane sees water that gets saltier along its length, so the calculator uses the average feed-side concentration, Cf × ln(1 / (1 − R)) / R, times the salt passage (1 − rejection).
  • Concentrate TDS: from the salt balance, Cc = (Qf Cf − Qp Cp) / Qc. The concentration factor is Cc / Cf, close to 1 / (1 − R).
  • Osmotic pressure: a rule of thumb of about 0.7 bar per 1,000 mg/L for sodium-chloride-type water. The feed pump has to beat this at the concentrate end, plus the membrane’s own resistance.

Worked example

A brackish RO unit takes 10 m³/h of feed at 1,500 mg/L TDS, runs at 75% recovery, and its membranes reject 99% of the salt:

StepCalculationResult
Permeate flow0.75 × 107.5 m³/h
Concentrate flow10 − 7.52.5 m³/h
Average feed-side TDS1,500 × ln(4) / 0.752,773 mg/L
Permeate TDS0.01 × 2,77327.7 mg/L
Concentrate TDS(10 × 1,500 − 7.5 × 27.7) / 2.55,917 mg/L
Concentration factor5,917 / 1,5003.94×
Concentrate osmotic pressure0.7 × 5.917about 4.1 bar

For an electrolyser, 27.7 mg/L is still far too salty: the feed water usually needs a second RO pass and an EDI or mixed-bed polisher after this. See the electrolyser water calculator.

Things that change the answer

  • Scaling: the higher the recovery, the more the hardness and silica concentrate. Scaling, not the membrane, usually limits recovery.
  • Temperature and age: warm water and older membranes pass more salt. Design on end-of-life rejection.
  • Ion mix: rejection differs by ion. Boron, carbon dioxide and silica pass far more than sodium chloride does.
  • Projections: for a real design, run the membrane maker’s projection software with a full water analysis.