CALCULATOR · WATER TREATMENT
RO recovery, reject and permeate quality
Flow and salt balance for a reverse osmosis unit: permeate, concentrate (reject), their TDS and the concentration factor. Results update as you type.
Permeate flow / feed flow. Brackish water often 70 to 80%; seawater often 40 to 50%.
From the membrane data sheet; real systems often run a little below the nominal figure.
Mass balance only.
How the calculator works
- Flows: permeate Qp = R × Qf; concentrate Qc = Qf − Qp, where R is the recovery.
- Permeate TDS: the membrane sees water that gets saltier along its length, so the calculator uses the average feed-side concentration, Cf × ln(1 / (1 − R)) / R, times the salt passage (1 − rejection).
- Concentrate TDS: from the salt balance, Cc = (Qf Cf − Qp Cp) / Qc. The concentration factor is Cc / Cf, close to 1 / (1 − R).
- Osmotic pressure: a rule of thumb of about 0.7 bar per 1,000 mg/L for sodium-chloride-type water. The feed pump has to beat this at the concentrate end, plus the membrane’s own resistance.
Worked example
A brackish RO unit takes 10 m³/h of feed at 1,500 mg/L TDS, runs at 75% recovery, and its membranes reject 99% of the salt:
| Step | Calculation | Result |
|---|---|---|
| Permeate flow | 0.75 × 10 | 7.5 m³/h |
| Concentrate flow | 10 − 7.5 | 2.5 m³/h |
| Average feed-side TDS | 1,500 × ln(4) / 0.75 | 2,773 mg/L |
| Permeate TDS | 0.01 × 2,773 | 27.7 mg/L |
| Concentrate TDS | (10 × 1,500 − 7.5 × 27.7) / 2.5 | 5,917 mg/L |
| Concentration factor | 5,917 / 1,500 | 3.94× |
| Concentrate osmotic pressure | 0.7 × 5.917 | about 4.1 bar |
For an electrolyser, 27.7 mg/L is still far too salty: the feed water usually needs a second RO pass and an EDI or mixed-bed polisher after this. See the electrolyser water calculator.
Things that change the answer
- Scaling: the higher the recovery, the more the hardness and silica concentrate. Scaling, not the membrane, usually limits recovery.
- Temperature and age: warm water and older membranes pass more salt. Design on end-of-life rejection.
- Ion mix: rejection differs by ion. Boron, carbon dioxide and silica pass far more than sodium chloride does.
- Projections: for a real design, run the membrane maker’s projection software with a full water analysis.
Need help with a water treatment train? Talk to Avoltium about a one-hour expert call.