Pipe Pressure Drop Calculator

CALCULATOR · PIPING

Pipe pressure drop and velocity

Velocity, friction factor and pressure drop for a liquid in a full pipe, by the Darcy–Weisbach equation, plus the pressure needed to lift it. Results update as you type.

Water: 0 to 150 °C.

Filled in for water.

Filled in for water.

Sets the inside diameter. Inside diameters per ASME B36.10.

Type your own for other schedules or materials.

Commercial steel: 0.045. Plastic pipe: about 0.0015 to 0.007. Old, corroded steel: much higher.

Long-radius elbow about 0.2 to 0.3, gate or ball valve open about 0.05 to 0.2, swing check valve about 2, pipe exit 1.0.

Negative if the line runs downhill.

TOTAL PRESSURE NEEDED–
FRICTION PRESSURE DROP–
HEIGHT (STATIC) PRESSURE–
FRICTION HEAD LOSS–
VELOCITY–
PIPE DROP PER 100 M–
REYNOLDS NUMBER–
FRICTION FACTOR (DARCY)–

Single-phase liquid, full pipe, constant density. Not for gas lines with large pressure drops.

How the calculator works

Liquid rubbing along the pipe wall and swirling through fittings loses energy. The Darcy–Weisbach equation turns that loss into a head (metres of liquid) and then a pressure.

  • Velocity: v = Q / A, with A = π D² / 4.
  • Reynolds number: Re = ρ v D / μ. Below about 2,300 the flow is laminar; above about 4,000 it is turbulent.
  • Friction factor: f = 64 / Re in laminar flow, otherwise from the Colebrook equation with the pipe’s relative roughness ε / D.
  • Head loss: hL = (f × L / D + ΣK) × v² / (2g), with g = 9.80665 m/s².
  • Pressure drop: Δp = ρ g hL. The height pressure ρ g Δz is added for a line that climbs.

The friction factor here is the Darcy (Moody) factor. Some older charts use the Fanning factor, which is a quarter of it.

Worked example

Water at 20 °C, 100 m³/h through 100 m of DN150 Sch 40 steel pipe (inside diameter 154.1 mm, roughness 0.045 mm), fittings adding up to K = 3.0, outlet 10 m above the inlet:

StepCalculationResult
Water at 20 °Cρ = 998.2 kg/m³, μ = 1.002 mPa·s–
Velocity0.02778 m³/s / 0.01865 m²1.49 m/s
Velocity head1.49² / (2 × 9.80665)0.113 m
Reynolds number998.2 × 1.49 × 0.1541 / 0.001002228,600
Friction factorColebrook, ε / D = 0.000290.0174
Pipe loss0.0174 × 100 / 0.1541 × 0.1131.28 m
Fittings loss3.0 × 0.1130.34 m
Friction pressure drop998.2 × 9.80665 × 1.62 / 1,00015.8 kPa (0.158 bar)
Height pressure998.2 × 9.80665 × 10 / 1,00097.9 kPa
Total15.8 + 97.9113.7 kPa (1.137 bar)

The same flow in DN100 would run at 3.4 m/s and lose about seven times as much to friction, which is why line sizing usually starts from a target velocity.

Things that change the answer

  • Pipe age: corrosion and scale raise the roughness and shrink the bore. Old steel lines can lose far more than a new-pipe calculation shows.
  • Fittings: K values vary between sources and sizes. For control valves, strainers and heat exchangers, use the vendor’s pressure drop instead.
  • Viscous liquids: heavy oils and glycol mixtures can be laminar even at normal velocities; the friction factor then depends on viscosity, not roughness.
  • Gases and flashing liquids: when density changes along the line, this method is not enough.

Related tools: Pump Power Calculator and NPSH Calculator.