Pump Power Calculator

CALCULATOR · PUMPS

Pump power and motor size

Hydraulic power, shaft power, electrical input and a standard IEC motor size from flow, head and efficiency. Results update as you type.

Total dynamic head at the duty point.

Water at 20 °C: 998. Seawater: about 1025.

Read it from the pump curve at the duty point.

API 610 style: 25% up to 22 kW, 15% from 22 to 55 kW, 10% above 55 kW of shaft power.

Any currency; the cost result uses the same one.

HYDRAULIC POWER–
SHAFT POWER–
ELECTRICAL INPUT–
SUGGESTED MOTOR (IEC)–
ENERGY PER YEAR–
ENERGY COST PER YEAR–

Preliminary sizing only. Confirm against the pump curve, the motor data sheet and your project specification.

How the calculator works

The pump adds energy to the liquid. That useful energy per second is the hydraulic power. The pump and motor lose some energy on the way, so the shaft power and the electrical input are higher.

  • Hydraulic power: Ph = ρ × g × Q × H, with ρ in kg/m³, g = 9.80665 m/s², Q in m³/s and H in m. Divide by 1,000 for kW.
  • Shaft (brake) power: Ps = Ph / ηpump
  • Electrical input: Pe = Ps / ηmotor
  • Motor size: the next standard IEC rating at or above Ps × (1 + margin).

Worked example

Water at 20 °C (ρ = 998 kg/m³), 100 m³/h against 50 m of head, pump efficiency 70%, motor efficiency 93%:

StepCalculationResult
Flow in m³/s100 / 3,6000.02778 m³/s
Hydraulic power998 × 9.80665 × 0.02778 × 50 / 1,00013.59 kW
Shaft power13.59 / 0.7019.42 kW
Electrical input19.42 / 0.9320.88 kW
Motor (API 610 style, 25% below 22 kW)19.42 × 1.25 = 24.3 kW → next IEC size30 kW

Things that change the answer

  • Run-out: a centrifugal pump that runs further right on its curve can need more power than at the duty point. Size the motor for the highest flow the system allows, not only the rated point.
  • Viscous liquids: efficiency falls and power rises with viscosity. Correct the water curve before using this calculator.
  • Specific gravity: power scales directly with density. A pump tested on water needs a bigger motor on a heavier liquid.
  • Project rules: many specifications set their own motor margins. Use theirs where they differ.

Related guide: NPSH Explained: How to Avoid Pump Cavitation.

Need a second opinion on a pump selection? Talk to Avoltium about a one-hour expert call.